Fifteen samples of Procera® AllCeram core material were tested against enamel in a custom wear apparatus with human saliva. Silicone impression techniques were used to record the before and after sample profiles. Measurements with a stereomicroscope (64x) showed that wear for the abraded samples ranged from 90 + 180 mm, 15-60 mm for the polished and 210-315 mm for the glazed. When the Procera® aluminium oxide core is exposed and in contact with enamel, wear is reduced when the surface is polished with Brasseler Dialite System.
J Dent Res 1996 75 (spec issue) abstract 393.
Hacker et al |
Mean wear materials opposed by enamel sample | Mean wear of opposed enamel |
| Olympia gold | 0.32 um | 9.0 um |
| AllCeram porcelain | 4.3 um | 60 um |
| Ceramco porcelain | 3.7 um | 230 um |
Hacker CH, Wagner WC, Razzoog ME. An in vitro investigation of the wear of enamel on porcelain and gold in saliva. J Prosth Dent 1996; 75: 14-17.